Determination of Levofloxacin in Healthy Human Plasma by High Performance Liquid Chromatography (HPLC) Method

田俊生,杨佳凤,王跃飞,潘桂湘,高秀梅,张恒昆
DOI: https://doi.org/10.3969/j.issn.1673-9043.2007.02.011
2007-01-01
Abstract:[Objective] To establish a HPLC method for the determination of Levofloxacin in human plasma and to determine the concentration of Levofloxacin in human plasma after oral taking a single dose 200 mg of Levofloxacin tablet in 20 healthy volunteers.[Methods] Plasma sample was added with internal standard Tinidazole and extracted with chloroform.After taking out the layer of the chloroform it was extracted with 0.01 mol/L hydrochloric acid repeatedly and the acid solution was injected into the HPLC instrument for determination.[Results] There was no internal substance in plasma,which interfered with the determination of the samples.The linear range of medicine-containing blood was between 0.025~6.0 mg/L(r=0.999 5),the lowest quantified limit was 0.025 mg/L.The average recovery of extract was more than 93.2%.All the RSD of precision of intra or inter-batch was less than 6.4% and the accuracy was between 89.7%~103.1%.[Conclusions] The method has a good specificity,can be manipulated conveniently.The obtained result is correct with high sensitivity.So it is a suitable method for the determination of Levofloxacin.
What problem does this paper attempt to address?