Study of RS-485 Bus Ethernet Interface Conversion Device

GONG Quan-cheng,WU Ya-feng,LI Jiang-hong
DOI: https://doi.org/10.3969/j.issn.1000-3428.2012.22.062
2012-01-01
Abstract:Earlier serial port and Ethernet interface conversion is realized by pure hardware.It has features of high data transmission speed,but function single as well as poor flexibility.Due to these disadvantages,interface conversion system based on ARM9 is proposed.MOXA UC-7101 is utilized as hardware.Application program is developed under μCLinux embedded OS.System communication follows modbus protocols.When net is connected,SD card data can be retrieved correctly according to net instruction,and data between monitor center and lower RTU can be transferred correctly and timely.System test results show that MOXA begins to poll RTU and response data is stored into SD card while net is shut off.
What problem does this paper attempt to address?