Applied Investigation on LED Heat Cooling Equipment Using Flat Micro-Heat Pipe Arrays

Wang Hongyan,Deng Yuechao,Hao Limin,Zhao Yaohua
DOI: https://doi.org/10.3969/j.issn.1003-353x.2012.03.017
2012-01-01
Abstract:The flat micro-heat pipe arrays with miniature axially grooves for LED cooling were constructed.The experiments show that the flat micro-heat pipe arrays has the highest heat flux of evaporator,which is 143. 2 W/cm2 when the temperature on the evaporator is 69.5 ℃.The high e fficient heat cooling equipments of LED using flat micro heat pipe arrays were d esigned and a series of experiments were carried out.The results show that the base temperatures of LED are below 70 ℃,much lower than the junction tempe rature of LED. The numerical simulation results show that the error between the experiments an d simulation results is within 4% and there is a good agreement.The numerical m odel can be used in the optimization of the LED cooling equipment.
What problem does this paper attempt to address?