Experiment and Capacity Calculation Theory Research of Hybrid GFRP-concrete-steel Double Skin Tubular Columns under Axial Compression

王俊,刘伟庆,方海,祝露
DOI: https://doi.org/10.19701/j.jzjg.2012.02.027
2012-01-01
Abstract:Through axial compression experiment of four solid and hollow hybrid GFRP-concrete-steel double skin tubular short columns,the working principle,failure mode,GFRP tube constraint effect and core concrete constitutive relation,as well as their influence factors under whole axial loading,were contrasted and analyzed.The results indicate that,if other conditions are same,deforming ability of hollow hybrid columns exceeds that of solid hybrid columns,while axial bearing capacity and GFRP constraining effect to concrete are lower than those of solid hybrid columns.Smaller the ratio of GFRP tube's diameter and wall thickness owe,better the restraint effect of GFRP tube is.In the same condition of GFRP tube diameter and wall thickness ratio,the maximum concrete stress of solid columns is larger than that of hollow columns,while the maximum strain is smaller than that of hollow columns.Confined concrete strength was analyzed through tests,then the axial bearing capacity calculation formulas of solid and hollow hybrid columns were derived by ultimate equilibrium method.Experiment results confirmed the good agreement with the formula results.
What problem does this paper attempt to address?