Changes in joint pain and flexion angle in patients following different arthroscopic radiofrequency wands
Ye Ping,Chen Jian,Ni Lei
DOI: https://doi.org/10.3969/j.issn.1673-8225.2009.35.037
2009-01-01
Abstract:OBJECTIVE: To observe the short-term effect of two different arthroscopic radiofrequency wands on pain-relieving and functional recovery postoperative arthroscopy. METHODS: A total of 60 patients underwent arthroscopy were selected from the Department of Orthopedics, People’s Hospital Affiliated to Peking University between November 2005 and November 2007, including 18 males and 42 females, aged 15-72 years, averagely 48 years. All enrolled patients were equally and randomly divided into experimental and control groups. Arthroscopic meniscus plasty was carried out in arthroscopy using VAPR3 system and ArthroCare2000 system. Exercise of strength in musculus quadriceps fexoris was conducted at 1 day after operation, and patients could do genuflex motion sitting. The pain in self-consciousness, ability in activities of daily living and the flexion angles of knee joint were evaluated by the same scale before operation and at 1, 2, 3 and 7 days after operation respectively. The higher the score was, the better the functional recovery was. RESULTS: A total of 60 patients were included in the final analysis. There was no significant difference in pain in self-consciousness between experimental and control groups at 1, 2, 3 and 7 days after operation [(7.22±1.69), (6.88±2.42) points; (8.33±1.49), (8.50±1.26) points; (9.03±1.25), (8.59±1.28) points; (9.17±1.21), (9.44±1.07) points]. There was no significant difference in ability to activities of daily living between experimental and control groups following operation except day 2 [(29.40±7.25), (27.10±11.10) points; (40.10±6.89), (45.30±5.61) points; (47.90±6.26), (49.10±5.89) points; (53.50±5.08), (55.10±5.03) points]. There was no significant difference in score of the flexion angles of knee joint between experimental and control groups at 1, 2, 3 and 7 days after operation [(2.50±1.86), (2.50±2.06) points; (4.50±1.86), (4.60±2.09) points; (6.33±1.64), (5.88±2.16) points; (7.83±2.87), (7.17±2.81) points]. There was no significant difference in comprehensive score between experimental and control groups at 1, 2, 3 and 7 days after operation [(44.70±8.60), (41.60±11.90) points; (58.80±8.85), (64.40±8.03) points; (70.40±8.23), (71.60±8.07) points; (78.10±7.25), (79.20±6.42) points]. CONCLUSION: The effect of two different arthroscopic radiofrequency wands were similar in short-term effect postoperative arthroscopy.