Evaluation of PCDD/Fs emission from fluidized bed incinerators co-firing MSW with coal in China

J.H. Yan,T. Chen,X.D. Li,J. Zhang,S.Y. Lu,M.J. Ni,K.F. Cen
DOI: https://doi.org/10.1016/j.jhazmat.2005.12.007
IF: 13.6
2006-01-01
Journal of Hazardous Materials
Abstract:The levels and homologue profile of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from stack gas of three typical fluidized bed incinerators co-firing municipal solid waste (MSW) with Chinese coal were measured. The PCDD/Fs emission was in the range of 0.0054–0.1961ngI-TEQ/Nm3. Comparison of PCDD/Fs detection results by HRGC/HRMS and HRGC/LRMS suggested that it was feasible to detect fly ash with high PCDD/Fs concentration by HRGC/LRMS. Several factors on PCDD/Fs emission were discussed. The primary reason for the lower PCDD/Fs emission was the inhibition mechanism of relatively high sulfur in feeding coal on PCDD/Fs formation. The emission results also showed that there was no directly correlation between PCDD/Fs levels and CO, O2 and HCl concentration in flue gas. It was estimated that about 0.1034gI-TEQ was annually emitted to atmosphere from the tested three MSW incinerators (total daily treatment capacity is 800tonnesMSW).
What problem does this paper attempt to address?