Problems in ethyl benzene/styrene fractionator and countermeasures

Ma Xianbo,Feng Jiandong
DOI: https://doi.org/10.3969/j.issn.1002-106X.2011.06.007
2011-01-01
Abstract:The causes of failure to reach design capacity of EB/styrene fractionator were analyzed,including low feed temperature,increased gas velocity of empty tower and pulsation of tower bottom pressure,etc.Effective measures were proposed such as addition of feed heater and reduction of heat exchange area of tower bottom reboiler,etc.After revamping,the processing capacity of fractionator tower has reached 103% of design capacity,which can fully meet the production requirements.In addition,the unit product's energy consumption is greatly reduced.
What problem does this paper attempt to address?