Effect of Residual Charges on Surface Discharge Propagation under Impulse Voltage

邓军波,松岗成居,熊田亚纪子,日高邦彦,蒲路,张冠军
2012-01-01
Abstract:For a high-voltage electrical apparatus,its surface insulation is always the weakest point,and many accidents are initiated from surface discharge.After the discharge,charges accumulate on the insulator surface,and these residual charges will significantly influence the onset and development of the subsequent discharge.Therefore,we studied surface discharges on the polyethylene terephthalate(PET)film with a coaxial cylindrical configuration by high speed camera under impulse voltages with alternate voltage polarity,and measured the surface potential distribution induced by residual charges after discharges by an electrostatic probe.With the residual charges from surface discharge with opposite polarity,the subsequent discharge propagates by partly following the path of the previous discharge.The discharge current of the surface discharge will be strengthened by the residual charges with the opposite polarity.Along the direction of discharge channel,the surface charge potential distribution can be divided into two parts,i.e.,20 mm area ahead of discharge with bigger potential gradient,to be streamer discharge,and smooth potential gradient area along the main channel of discharge,to be leader discharge.