Nervous dysfunction in the procedure of pacemaker implantation

SHENG Qin-hui,WANG Yu-chuan,ZHOU Jing,JIANG Jie,LI Kang,DING Yan-sheng
DOI: https://doi.org/10.3969/j.issn.1007-2659.2010.01.006
2010-01-01
Abstract:Objective To analyze the possible reasons which induce nervous dysfunction during the implantation of cardiac pacemaker.Method An analysis was performed in the patients with abnormalities of neural dysfunction in the procedure of pacemaker implantation in our hospital from January 1,2006 to March 1,2009.Results Seven patients had the complication of neural dysfunction in the procedure of implanting pacemaker,whose incidence was 1.91%.The average age was 78±6.8 years,and the major presentations included anarthria,nausea,vomiting,and faint consciousness.The systolic and diastolic blood pressure was 190±15.4/102±15.6 mmHg at the beginning of procedure,which was much more higer than before(P<0.000 1).Conclusion Nervous dysfunction may be a transient symptom,and is mostly induced mainly by stress,blood pressure fluctuation,and pain.
What problem does this paper attempt to address?