The Establishment of Animal Model of Extracorporeal Circulation in Rats

HEI Fei-long,GAO Guo-dong,ZHOU Rong-hua,LONG Cun,WEN Fu-xing,GUAN Bin,SHI Shi-yong
2006-01-01
Abstract:OBJECTIVE To establish the animal modal of extracorporeal circulation(ECC) in the rats.METHODS 12 male SD rats were anesthetized and assigned to undergo 60 min of ECC.The femoral artery,the right external jugular vein and the left femoral vein were cannulated.ECC were performed with the left femoral artery perfusion at a flow rate of 160 to 180 ml/(kg·min).During the whole process,the hemodynamics,electrocardiograph(ECG) and blood-gas analysis were observed.RESULTS 9 of the 12 animals were performed successfully.The hamodynamic parameters were steady and blood-gas analysis normal during whole process.After ECC weaning,cardiovascular and respiratory functions recorvered rapidly.CONCLUSION The rat model of ECC established via the right external jugular vein and the left femoral vein drainage and the left femoral artery perfusion is safe,reliable,steady and utility.It is an ideal model for studying multiple organ dysfunctions induced by ECC,especially for cerebral damage and protection experimental research during ECC.