FACTORS INFLUENCING DISINFECTION EFFICACY OF ATMOSPHERIC PRESSURE GLOW DISCHARGE PLASMA

JIANG Yu,QIN Ke-qin,ZHANG Shan-duan,SONG Wei-min
DOI: https://doi.org/10.3969/j.issn.1001-7658.2007.02.001
2007-01-01
Abstract:Objective To study the factors influencing germicidal efficacy of atmospheric pressure glow discharge plasma. Methods Quantitative carrier test method was used to carry out laboratory observation on the influencing factors such as different bacterial species,amount of bacteria on carrier,different carriers,different exposure methods and different organic substances. Results Direct exposure to atmospheric pressure glow discharge plasma for 30 s killed 99.91% and 99.99% of Escherichia coli and Staphylococcus aureus respectively,while indirect exposure to atmospheric pressure glow discharge plasma for 120 s killed 99.97% and 99.99% of the 2 above bacteria respectively.The efficacy of plasma of direct exposure-type disinfector in killing E.coli on glass surface was significantly lower than that in killing the bacteria on other two carriers,the efficacy in killing E.coli on paper surface was the best and that in killing the bacteria on cloth strip was between the former two.Above 30%(v/v) of calf serum and glycerin content could significantly decrease the efficacy of plasma in killing bacteria on surfaces and the germicidal efficacy decreased with increasing organic substance content. Conclusion The efficacy of direct exposure method of plasma in killing bacteria on glass slide is significantly higher than that of indirect exposure method.Factors such as different bacterial species,different bacterial carriers and organic substance can influence the germicidal efficacy of plasma.