The Extraction of Fuzzy Rules and Control for Deposit Dimension in Spray Forming Process

Y. D. Qu,S. B. Chen,C. S. Cui,R. D. Li,Z. T. Ma,C. X. Li
DOI: https://doi.org/10.1007/978-3-540-73374-4_53
2007-01-01
Abstract:A fuzzy controller (FC) was developed to improve deposit dimension accuracy in spray forming process, fuzzy rules of FC were extracted from experimental sample data by dynamic clustering method. Simulation results show that fuzzy controller is available to regulate deposit dimension, main advantage of FC is it has a stronger adaptability for nonlinear process control than PID controller, and FC of identical structure has satisfying control performance for different predetermined target values. FC closed-loop control experimental results show that average deposit thickness is 5.22m in steady growth period, average error between actual size and 5.5mm target value is 0.28mm, and RMS (mean square root) is 0.31mm.
What problem does this paper attempt to address?