Measurement of ultrasonic guided waves excited by Golay code in long bone

Song Xiaojun,Wang Weiqi
DOI: https://doi.org/10.3969/j.issn.0254-3087.2012.03.007
2012-01-01
Abstract:Using ultrasonic guided waves(GWs) to evaluate long bones has gained more and more attention recently.However,the GWs will suffer high attenuation when they propagate in cortical bone.It is hard to receive the guide waves,especially when there is soft tissue on the cortical bone.Therefore,in order to improve the signal to noise ratio(SNR) and amplitudes of the receiving signals,this paper proposes a method that uses Golay coded excitation to obtain GWs.In simulation,the L(0,5) mode was obtained through Golay coding and decoding,which is exactly the same as that excited by single pulse.This result suggests the feasibility of using Golay code to obtain GWs.In the experiment of bovine bones in vitro,the GW waveforms obtained from Golay coding and single pulse excitations basically agree with each other.Golay coding can improve the SNR and also can increase the measuring distance of GWs,which demonstrates that applying Golay coding to measure ultrasonic GWs has great potential.
What problem does this paper attempt to address?