Abstract:Objective To test and compare the effect of different methods to fasten the cables used in Brooks instrumentation for atlantoaxial instability.Methods On the WD-5 mechanics experimental machine,the parameters including the strain,displacement,strength,rigidity,torque and torsion angle are quantified under the conditions such as flexion,extension,lateral bending and rotation for the normal complex(Group N),atlantoaxial instability complex(Group M),and the other groups of different methods to fasten the cables used in Brooks instrumentation(Group A,B,C).Results The strength,strain,load displacement of Group A which were fixed by the new double locking titanium cable fixation system were superior to those of the other groups(P<0.05).The effect of fastening the cable in both sides at the same time was better than that of fastening half side of the cable in turn(P<0.05).The effect of re-fixation after a rest was better than just fastening the cable in both sides at the same time(P<0.05).Conclusion The effect of titanium cable Brooks fixation is the best when we fasten the specimen in both sides at the same time again after a rest.Since the change of locking method,the biomechanical characteristics of the new type double locking titanium cable fixation system were superior to the imported titanium cable.