Optimization of Laser Micromachining Parameters for Biomedical Titanium

张松,胡金玲,王强,张春华,刘常升
DOI: https://doi.org/10.3969/j.issn.1000-1646.2008.04.014
2008-01-01
Abstract:Laser microdrilling with compressed air as adjuvant gas was performed using 400 W Nd:YAG laser to improve the surface properties of biomedical titanium and enhance the bonding strength between the implant and bone.The influence of the drilling parameters on the shape of microholes was studied.The experimental results show that both diameter and depth of microholes increase with increasing pulse energy,pulse width and pulse number.The depth of microholes is not affected by pulse frequency while the diameter of microholes increases with the pulse frequency.Regularly patterned microholes can be produced with the optimized microdrilling parameters on pure titanium,which is favorable for extending application of biomedical titanium in clinic.
What problem does this paper attempt to address?