Pretreatment of Micro-polluted Source Water with High Turbidity by Contact Oxidation/Biofiltration Process

Hong-yu LU,Wen-zhuo LIN,Zhi-qiang CHEN
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2010.03.020
2010-01-01
Abstract:The combined process of biological contact oxidation and biofiltration was applied to pretreat micro-polluted source water with high turbidity. A comparison was made between the combined process and biological aerated filter (BAF) process. The results show that the average removal rates of COD_(Mn), and UV_(254) by the combined process are 33.3% and 23.4%, higher than those by BAF. Howev-er, the removal rates of nitrite nitrogen and ammonia nitrogen are 81.7% and 82.6%, slightly lower than those by BAF. The average removal rate of turbidity is 74.2%, being 30% higher than that by BAF. An average of 23.1% flocculant dosage is saved using the combined pretreatment process com-pared to the process without biological pretreatment, which is larger than the 11% dosage saved by BAF.
What problem does this paper attempt to address?