Biofilm formation and startup of nitrification biological aeration filter

Wang Jianhua,Chen Yongzhi,Peng Yongzhen
2010-01-01
Abstract:In recent years,biological aerated filters are widely applied in sewage nitrification process,nitrifying biological aerated filter emerges because of demand.The effect of organic pollutants on the startup of nitrifying BAF was investigated by using natural biofilm formation compound with quick exhaust sludge biofilm formation.Under the conditions of T=19℃,HRT=55 min,effluent DO=8 mg/L and influent NH+4-N about 50 mg/L,the startup time of both nitrifying BAF was different,the first nitrifying BAF needed only 18 days,when it was steady running,NH+4-N removal efficiency reached 100%,the second nitrifying BAF,while,needed 24 days when it was steady running,the removal efficiencies of COD and NH+4-N were 84.6% and 91.2%,respectively.The results showed that,compared with real sewage containing organic pollutants,the startup time of the first nitrifying BAF fed with artificial wastewater without organic pollutants decreased by 6 days.This was mainly because the yield coefficient of heterotrophic organisms was greater than nitrifying bacteria.
What problem does this paper attempt to address?