Detection of heavy metal ions in aqueous solution by P(MBTVBC-co-VIM)-coated QCM sensor

Zheng Cao,Junkang Guo,Xiao Fan,Junting Xu,Zhiqiang Fan,Binyang Du
DOI: https://doi.org/10.1016/j.snb.2011.03.023
2011-01-01
Abstract:A novel copolymer P(MBTVBC-co-VIM) was designed and successfully synthesized for the fabrication of copolymer-coated QCM sensors to detect the heavy metal ions in aqueous solution. The copolymer P(MBTVBC-co-VIM) contains many nitrogen (N) and sulfur (S) atoms in the side groups as electron donors, which can easily form complexes with heavy metal ions. The strong interaction between the S atom and Au electrode of quartz crystal further assures the stability of copolymer thin films on the quartz crystal surface in aqueous media. The QCM results indicated that the P(MBTVBC-co-VIM)-coated sensor exhibited high sensitivity, stability and selectivity for the detection of Cu2+ in aqueous solution. The lowest detection limit can reach 10ppm Cu2+ in aqueous solution, which resulted in the frequency shift of 3.0Hz (ΔF3/3). The P(MBTVBC-co-VIM)-coated QCM sensors had porous surface morphologies as revealed by AFM investigation. Such porous structures enhanced the surface areas of the copolymer thin films, which increased the contacting probability of N and S atoms with heavy metal ions in solution and improved the detection sensitivity of the copolymer-coated QCM sensors.