Temperature Response and Seismic Analysis of Super-length Structure with Long-span Connecting Building

Li Zhengyu,Liu Jingbo,Liu Yangbing,Shi Meng,Wang Binfu,Huang Yu,Wen Hui
2007-01-01
Abstract:The temperature response of super-length structure with long-span connecting building is obvious,and it is necessary to conduct the temperature response analysis of the whole building.By taking Shangdi industry-commerce building as an example,three kinds of connecting projects are designed,and the whole deformation,drift angle of the main structure and the connecting structure,the internal forces of the floor and some members are studied under the thermal action.The results show that considering the thermal effects,two projects can't satisfy the deformation limit under the normal service condition and the connecting structural floor internal forces.The hinge support on one side and gliding surpport on the other side is selected as the fitting structure scheme.The seismic response spectra,elastro-time-history and elastro-plastic-time-history are made.The results illustrate that the selected scheme can overcome the temperature problem caused by the overlong structure,and satisfy the demands of the code for Seismic Design of Buildings.
What problem does this paper attempt to address?