Study on treating p-nitrophenol wastewater with HL-centrifugal contactor

Xu Jinquan,Duan Wuhua,Zhou Xiuzhu,Zhou Jiazhen
DOI: https://doi.org/10.3969/j.issn.1673-9108.2006.10.028
2006-01-01
Abstract:Solvent extraction is an effective way to treat and recover the p-nitrophenol from high content wastewater at present.An experimental study on treating the p-nitrophenol wastewater has been carried out with QH-1 and the HL-centrifugal contactor.Results show that the distribution coefficient of the p-nitrophenol is 1103.4 for p-nitrophenol/HNO_3 solution-QH-1 system,and when the Φ20 mm HL-centrifugal contactor is used for extracting,both the extraction stage efficiency E of the single-stage and the extraction rate ρ of the three-stage cascade can reach more than 99% at suitable operation conditions,and the back-extraction rate of the three-stage cascade can also reach more than 98% under suitable operation conditions.
What problem does this paper attempt to address?