Research on the Characteristic of Dyeing-Printing Wastewater Treatment with Micro-Aerobic Granular Sludge
Zhu Lingfen,Gao Ruqin,Wang Zhe,Wang Yangyang,Zhang Runtao,Liu Lili
DOI: https://doi.org/10.1016/j.egypro.2011.10.612
2011-01-01
Energy Procedia
Abstract:In order to provide a new method for the treatment of printing and dyeing wastewater, the experiment studies how to treat dyeing-printing wastewater by IC reactor, refluent tank (10L), self-regulating control valve making of medical infusion, air flow meter which the basic units of (mL/min), dissolved oxygen instrument, aerator pumps (3.5W) and aeration equipment under the micro-aerobic condition; The prophase experiment is that wastewater was flocculated. The step is: first, PH of the printing and dyeing wastewater would be changed to 7.5 or so, then, wastewater and flocculants (10% PAC flocculants and 0.05% PAM coagulant aids) were mixed and the mixing ratio of was 400 to 1. at last, the decolorizing ratio was stable at 46% approximately; after the biodegradability of dyeing wastewater improving, under the dissolved oxygen -0.3 similar to 0.5mg/L (ms) condition, the printing and dyeing wastewater (my) was diluted by domestic sewage which mixing ratio is 7 to 3. Then added the printing and dyeing wastewater gradually, and held the increase ratio of influent COD load as 7% and mixed water COD load steadily as 25%. When the influent load reached 4655.1mg / L or so, dissolved oxygen was 0.3 similar to 0.5mg / L, HRT was 6h, the reactor worked best, this moment, the removal rate of COD could reach 85.8%; when the micro-oxygen granular sludge can deal with printing and dyeing wastewater effectively, under the appropriate influent load, compared the influence of two micro-oxygen conditions of the dissolved oxygen concentration 0.5 similar to 0.8 (mg/L) and 0.8 similar to 1.0 (mg/L) on system performance to that of the higher concentration of dissolved oxygen 1.0 similar to 1.2(mg/L) in the runback water; In order to create a good living environment for granular sludge, during the experiment, inoculation sludge, pH of influent and effluent, influent load operation, HRT are controlled strictly, as a result, it is discovered that the temperature change affects the decolorization. At about 15 degrees C, the decolorization rate is very low, only about 12.7 percent, however, when the temperature at around 25 degrees C, the decolorizing rate increases rapidly, about 75.8%; at around 35 degrees C, the decolorizing rate tends to maintained slowly at around 80.7 percent. (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the Organizers of 2011 International Conference on Energy and Environmental Science.