PILOT SCALE STUDY ON PRINTING AND DYEING WASTEWATER TREATMENT WITH IRON-CARBON MICROELECTROLYSIS-BIOFILM-ADVANCED OXIDATION PROCESS
Bo ZHANG,Yong-jie QI,Su-ying JIANG,Jing XIE,Jun-bo LI,Chang XU,Xiang-yang WU,Zhi-ren WU
DOI: https://doi.org/10.13205/j.hjgc.201803009
2018-01-01
Environmental engineering
Abstract:In the pilot scale study,the printing and dyeing wastewater was treated by iron-carbon microelectrolysis-biofilm-advanced oxidation process.The treated wastwater capacity was 7.2 t/d and the typical characteristics of the raw wastwater were as follows:COD of 800 ~ 1 200 mg/L,BOD5 of 150 ~ 280 mg/L,chroma of 280 ~ 350 times,TN of 20 ~ 35 mg/L,NH3-N of 15 ~25 mg/L,TP of 0.4 ~ 0.7 mg/L.The treatment effect with the combined process showed that the effluent quality was stable and the results were as follows:COD of 15 ~ 35 mg/L,BOD5 of 10 ~ 15 mg/L,chroma of 2 ~ 5 times,TN of 4 ~ 6 mg/L,NH3-N of 1 ~ 3 mg/L,TP of 0.05 ~0.1 mg/L.And the effluent quality met the emissions standard for the textile dyeing and finishing industry of the "Discharge Standard of Main Water Pollutants for Municipal Wastewater Treatment Plant & Key Industries of Taihu Aera" (DB 32-1072-2007).The cost of operation was RMB 3.514 Yuan/t.The degradation products were analyzed by UV spectrum scanning and the results showed that the organic pollutants in the wastewater were decomposed into CO2,H2O,etc.