Characteristics of Computed Tomography Multiplanar Reconstruction in Assessing Interbody Fusion

Xu Feng,Zhou Yue,Chu Tongwei
DOI: https://doi.org/10.3969/j.issn.1672-9935.2007.08.003
2007-01-01
Abstract:Objective To investigate the characteristic of computed tomography multiplanar reconstruction(CTMPR)in assessing interbody fusion and find a new way to assess interbody fusion quantitatively.Methods Thirteen patients with lumbar fusion underwent CT scanning 1 week,3 months and 6 months postoperatively.CT attenuation of bone inside the cage was measured with Hounsfield units.Results The initial value of transplanted graft bone was(619.52±26.97)Hu,gradually increased to(628.69±42.60)Hu 3 months postoperatively,and(657.77±37.43)Hu 6 months postoperatively.It had no difference between 1 week and 3 months,but had significant difference between 1 week and 3 months.Conclusion Hounsfield unit measurement can be performed with a high degree of accuracy in assessing interbody fusion.