Real-time substructure hybrid test system for earthquake response of isolated bridge using velocity control

Yuan Yong,Xiong Shishu,Zhu Hongping
DOI: https://doi.org/10.3321/j.issn:1671-4512.2008.08.033
2008-01-01
Abstract:The real-time substructure hybrid test system which based on velocity loading concept was developed to verify the isolation effects of nature rubber(NR),high-damping rubber(HDR) and super-high-damping rubber(HDR-S) bearing isolators in bridge structure.The rubber bearing isolators have velocity-dependent performance,and heavily depend on rate of loading.Compared with conventional test system,the developed test system considered the velocity-dependent performance of specimens,and controlled the tests procedure with velocity concept.Basing on the test results,the test system accuracy was confirmed.Compared with test results of the nature rubber and high-damping rubber bearing,the excellent isolation effect of super-high-damping rubber bearing to the total bridge structural system associated with the characteristics of the input seismic ground motion was also directly confirmed.
What problem does this paper attempt to address?