Flow Injection Chemiluminescence Determination of Flunarizine Hydrochloride

朱金枝,杜建修,鹿艳秋
DOI: https://doi.org/10.3969/j.issn.1000-0720.2008.09.017
2008-01-01
Abstract:Weak chemiluminescence(CL) signal is observed during the reaction of potassium permanganate with flunarizine hydrochloride in acidic solution.In the presence of formaldehyde,the CL signal was enhanced significantly.Based on these phenomena,the experimental conditions that affected the CL reaction were optimized and a new flow injection CL method for the determination of flunarizine hydrochloride was proposed.The CL signal was linearly dependent on the concentration of flunarizine hydrochloride in the range of 8.0×10-7~8.0×10-5 g/mL.The detection limit was 8×10-7 g/mL flunarizine hydrochloride and the relative standard deviation was 2.2% for 1.0×10-5 g/mL flunarizine hydrochloride solution in eleven replicate measurements.The proposed method was successfully applied to the determination of flunarizine hydrochloride in capsules.