Preliminary Results on Radiofrequency Ablation of Prostate Tissuenear Urethra With Protective Cooling of the Urethra

LI Min,GAO Chun-xiang,DU Zh,MI Xiu-qin,GAO Peisen,LIU Lei,WANG Shu-min
DOI: https://doi.org/10.3969/j.issn.1004-0951.2012.10.006
2012-01-01
Abstract:Objective:To evaluate the safe distance between the tip and urethra can protect the urethra by using cooling on radiofrequency ablation of prostate.Methods:11 thermal lesions were produced on both sides of the prostate in 4 dogs.Three-way Foley catheters(14 French) will be inserted into the bladder and used to allow continuous infusion with cold saline.To monitor needle localization by transperinea ultrasound and measure the distance between needle tip and urethra.With the use of contrast-enhanced imaging,we can observe the size of thermal lesions.Results:Four adult male dogs were divided into three groups.Group 1(n=4),a control group without additional protective cooling.Group 2(n=6),with protective cooling of the urethra.The distance of all the ten lesions between the tip and urethra is more than or equal to 0cm.Damage to the urethra was assessed independently in 4 quadrants using fisher exact test(P=0.005).The tip was inserted into urethra in one lesions of group 3.There was good correlation between the lesion sizes measured with multiplied data of the antero-posterior and transverse lengths as determined with contrast-enhanced imaging and pathological measurements,there is no significant differences in T-test method.Conclusion:The distance between the tip and urethra is equal to or 0cm can protect the urethra by using cooling.Contrast imaging dramatically improved the visualization of the thermal RF lesions and urethra.
What problem does this paper attempt to address?