Effect of Precipitator and Desulphurization Devices on the Removal of Mercury with Different Speciation in Coal-fired Flue Gas

XU Wei,WANG Juan,WANG Wen-hua
2010-01-01
Abstract:Ontario-Hydro method was employed to determine the concentration and speciation of mercury in the flue-gas emitted from a coal-fired boiler equipped with electrostatic precipitator(ESP) and wet flue gas desulphurization(WFGD).The mass balance of mercury was calculated.The results indicate that HgP could be removed efficiently by ESP.The removal efficiencies of Hg2+、Hg0 and total mercury by WFGD were 81.3%、53.8% and 62.1%,respectively.Mercury mainly emits as Hg0 with a percentage of more than 80% of total mercury.The total mercury balance was 91.17% between the coal and its combustion products.It was verified that the flue-gas cleaning devices of coal-fired power plant had significant impacts on mercury emission characteristics,which could be helpful to develop the integrated technology for precipitator,desulphurization and mercury removal.