Studies on Size and Lubricant Effects for Fluidic Self-Assembly of Microparts on Patterned Substrate Using Capillary Effect

Cheng Lin,Fangang Tseng,Ching-Chang Chieng
DOI: https://doi.org/10.1115/1.2912216
2008-01-01
Journal of Electronic Packaging
Abstract:Conventional pick-and-place technology platform in handling microscale component assembly processes has technical limitations in terms of capacity, efficiency, and accuracy. The fluidic self-assembly (FSA) approach employs a lubricant fluid carrying micropart flows over a target wafer patterned with binding sites, which results in part-substrate attachment. This technique transports microparts from one location to another with orientation control and parallel sorting. The present study demonstrates a FSA approach for fast, economic, and precise handling of microscale parts with square (few are in rectangular) shapes. The microparts fabricated from silicon-oxide wafers and ranging in size from 350x350x170 mu m(3) to 1000x1000x440 mu m(3) aligned and filled to designated sites in the substrate under water. The effects of micropart sizes and lubricants on the FSA processes are compared. This study provides a fundamental analysis for achieving and optimizing the self-alignment. The polymer or solder adhesion force of the square-patterned micropart immobilized at the larger binding sites were estimated to be 117 +/- 15 mu N and 510 +/- 50 mu N, respectively, which results in higher assembly yield of up to 100% for these samples.
What problem does this paper attempt to address?