Anti-corrosion Performance of Galvanized Steel Framing in Residential Environments in North America

KONG Gang,LIU ling-yan,Rob White,Doug Rouke
2010-01-01
Abstract:Residential steel structure is one of development directions of residential buildings and the influence of corrosion on the durability of residential steel structure is one of the key factors that blocks its popularization.The project Service life of galvanized steel framing for residential building launched by the International Lead Zinc Research Organization was to measure the corrosion rates of actual zinc and zinc alloy coatings on steel framing samples during seven-year exposure in four different typical home environments in the USA and Canada.The results show that the coating corrosion of galvanized steel samples with the coating weight 200~270 g/m2 was very small in those four kinds of environment and also was small for the samples with similar coating weight.The estimated life expectancy based on the maximum mass loss in all samples ranged from 258 to 964 years with an average of 574 years at all locations.It is clear that zinc coated steel components of a residential framing system will not be degraded by corrosion during the service life of a structure.Galvanized steel can be used as sustainable material in buildings.
What problem does this paper attempt to address?