Simulation and analysis of electromagnetic force on shield of canned motor

FENG Ying-hui,ZHANG Ji-ge,WANG De-zhong
DOI: https://doi.org/10.19356/j.cnki.1001-3997.2012.04.010
2012-01-01
Abstract:As one of the key parts inside canned motor,the shield functions as isolation physically,which integrity may affect operation safety of primary loop in plant.The shield is installed inside RCP,who is influenced by complex loads,such as alternating magnetic field and coolant flow field.Based on the harmonic analysis in electromagnetic field of the motor,the distribution of magnetic induction and electromagnetic force on the shield are obtained,which results show that,the electromagnetic force borne upon the shield within the iron core is distributed periodically in circumferential direction of the motor with the tangential force as main force.Meanwhile the electromagnetic force borne on the shield is larger than that on rotor shield,who shall decrease little by little starting from iron core along winding end.However,the decreasing rate shall be the maximum as departing from the axial position corresponding to iron core end.
What problem does this paper attempt to address?