Abstract:This paper proposes a method of diameter selection based on microsphere separation experiments,analyzing the reason of the microsphere can not be easily separated,and studying the feature and the fluid-working-state of the microsphere.An accurate slit structure and pulse current are used in the method to make rapid and precise microsphere separation.The method has advantages such as simple operation,low labor intensity,high efficiency and so on.The experimental results indicate the method is valid and fea-sible.The paper also provides a new method and a new programme which can meet technology requirements for selecting microsphere and ensure the quality of microsphere.