Electrochemical detection of morphine on poly(3,4-ethylenedioxy-thiophene) thin films

TANG Ke-zhong,HONG Yu-peng,LEI Xin,DING Shang-zhi,HU Ji-ming,ZHANG Jian-qing,CAO Chu-nan
DOI: https://doi.org/10.3785/j.issn.1008-9497.2009.02.019
2009-01-01
Abstract:Conducting poly(3,4-ethylenedioxy-thiophene) (PEDOT) thin films were prepared onto ITO glass by electrodepositing from aqueous electrolyte. Factors, e.g. deposition charge and deposition potential, affecting the electrochemical activity of conducting films towards the electrochemical detection of morphine, were evaluated. The conducting films prepared at the optimal preparation parameters, i.e. deposition charges of 20~40 mC (at 0.8 cm2 ITO surface) and deposition potential of 1.2 V (Ag/AgCl), were found to possess the highest electrochemical activity. PEDOT-modified electrode showed a good linear relationship between the current response and morphine concentration in the testing solution from 0.05 to 6 mmol·L-1, with a correlation coefficient of 0.995. A very low detection limit, 0.05 mmol·L-1, was obtained.