Experiment on the Measurement of Gas Flow Rate Using Tracer Gas Technique

ZENG Xian-yang,CHI Zuo-he,ZHENG Ming-guang,MA Yi-tai
DOI: https://doi.org/10.3969/j.issn.1005-0329.2011.09.002
2011-01-01
Abstract:Experiment on the measurement of gas flow rate using tracer gas technique in a 0.300m internal diameter and 90-degree bent pipe are presented,which CO and air are selected as tracer gas and gas stream.Results show that the bias of tracer gas concentration at sampling points by multi-points injection /sampling method are smaller than single-points injection /sampling method.There is a good correlation between the gas flow rates measured by using tracer gas technique and turbine flowmeter,which the relative errors are the range of-2.15%~1.69% when the tracer gas injection points on the upstream at bend with the distance of 7D~13D(D is the internal diameter of pipe),and the sampling points on the downstream at bend with the distance of 10D~14D.The farther distances of the tracer gas injection point and sampling point,the lower of the flow rate relative errors measured by using tracer gas technique and turbine flowmeter.The constant injection rate of tracer gas should match with the gas flow rate in the duct.It is a simple and effective method that gas flowmeter calibration with tracer gas technique on the large diameter industrial gas(not fully purified) pipeline transportation.
What problem does this paper attempt to address?