Introduction of a Micro-surgery Model Through Femoral Arterial and Venous Catheters in Mice

史宏博,RUTH Magayet,王尊,赵进顺,邹宝波
DOI: https://doi.org/10.3969/j.issn.1001-5132.2012.03.016
2012-01-01
Abstract:Through femoral arterial and venous catheters in mice, a micro-surgery model is introduced for sampling of arterial blood, and continuous intravenous infusion in the free-moving conscious mice. Some 8-to-10-week-old mice weighing 20-30 g were used in this study. After anesthesia by inhalation of isoflurane (5%), 1.5% of isoflurane was administered to the mouse during surgery. With the use of aseptic techniques, catheters were placed in the femoral artery for the measurement of arterial pressure and sampling of blood. Catheters placed in the femoral vein were used for infusions. The arterial and venous catheters, tunneled subcutaneously in the back of the neck in a lightweight tethering wire, were attached to a swivel device at the top of the cage. To prevent blood cruor, 20u heparin (12-15 μL.h-1) was continuously infused through a doublechannel swivel. All mice fully recovered after surgery (1-2 d). Infection rate was less than 6%. The blockage rate of artery catheters was less than 5% 7 days after micro-surgery operation. The femoral arterial and venous cannular surgery is proven to be a dynamic, safe, as well as efficient micro-surgery model, which can be widely applied in pharmacological, toxicological, and clinical experimental studies.
What problem does this paper attempt to address?