EXPERIMENTAL STUDY ON TREATMENT AND REUSE OF HIGH CONCENTRATION AMMONIA NITROGEN WASTEWATER FROM ELECTROLYTIC MANGANESE

Wang Qinian,Wang Fan,Yu Hongbing,Gao Xiaojuan
2013-01-01
Environmental engineering
Abstract:Electrolytic manganese wastewater contains high concentration of ammonia nitrogen,whose highest-level is at 13 000 mg/L.The available treatment technologies have many disadvantages.It was put forward the method to heat and reuse electrolytic manganese wastewater after removing chromium from it according to cleaner production principle.The experiment result showed that the consumption of electrolyte purifier reagent(H2O2、SDD)and current efficiency were almost the same as no reuse when 10 mL/L electrolytic manganese wastewater without chromium was reused to electrolytic manganese combined process.There was no unusual phenomenon such as nigrescence,dissolved and so on during electrolysis process.Electrolytic manganese metal products purity was up to 99.9% and could meet YB/T 051-2003 DJMnD standard.
What problem does this paper attempt to address?