Efficiency Optimization of 40 Kw CAC-ZVS Three-phase PWM Rectifier

MA Zhi-yuan,LI Rui,XU De-hong
DOI: https://doi.org/10.3969/j.issn.1000-100x.2011.06.022
IF: 5.967
2011-01-01
IEEE Transactions on Power Electronics
Abstract:The compound active clamping ZVS three-phase PWM rectifier can realize ZVS operation for all switches.In addition,the anti-parallel diode reverse recovery current of all switches is suppressed well.Space vector modulation can be realized with all the switching devices operating at the fixed switching frequency.And the switching voltage stress of all the power switch devices is only a little higher than the DC link voltage.In order to optimize the circuit efficiency,the resonant parameter of the auxiliary loop is optimized firstly.Then the auxiliary switch loss is optimized by loss breakdown.A 40 kW experimental platform is builded up and experimental results indicate that the efficiency of the CAC soft switching rectifier can be promoted to 97.9% by the optimization method.
What problem does this paper attempt to address?