Pretreatment of Refractory and High-Concentration Chemical Industrial Wastewater by Fenton Oxidation Process

Jiansheng HUANG,Yong GUO,Yi TANG,Haojie YANG,Ting GUO,Bin MU
DOI: https://doi.org/10.3969/j.issn.1001-3865.2011.08.009
2011-01-01
Abstract:It was difficult to treat refractory and high-concentration chemical industrial wastewater effectively by single bio-chemical process.Fenton oxidation process was very effective in reducing the quantity of refractory compounds,so it could be used as pretreatment process in the chemical industrial wastewater treatment system.Series of Fenton treatment runs were performed on chemical industrial wastewater to determine the effects of pH,the proportion of chemicals,chemicals-feeding quantity and reaction time on the treatment efficiency.Orthogonal experiment results showed that the optimum treatment conditions were pH=3.5,chemicals proportion(FeSO4·7H2O/H2O2) of 125.0 mg/mL,chemicals-feeding quantity was 1.6 mL of 50% H2O2 and 200.0 mg of FeSO4·7H2O to per 100.0 mL wastewater.Under these optimum conditions,59.0% of COD and 37.4% of NH3-N could be removed in only 5 min.The results indicated that after pretreated by Fenton oxidation,the biodegradability of refractory chemical industrial wastewater was greatly improved and benefit to subsequent wastewater treatment.
What problem does this paper attempt to address?