Simulation and Experiment on Air-Cooled Thermal Energy Management of Lithium-Ion Power Batteries

ZHANG Jiangyun,ZHANG Guoqing,ZHANG Lei,RAO Zhonghao
DOI: https://doi.org/10.3969/j.issn.1676-8484.2011.02.012
2011-01-01
Abstract:The air-cooled methods were used for cooling commercial LiFePO4 batteries to illustrate the effect of heat transfer enhancement. The commercial LiFePO4 batteries were tested at 15-35 A. The temperature distribution in a single battery was numerical ly simulated according to the experiment al data. Air flow across two and three batteries was simulated to illustrate the air-cooled effect. Experiment al and simulation results show that air-coola has a positive significance for the battery thermal management at discharging currents of 0-30 A. For discharging currents less than 30 A, the peak temperature in batteries is less than 50 ℃, while the temperature difference between batteries is still more than 5 ℃. When the discharging current is higher than 30 A, air-cooling for batteries and battery packs can not guarantee evenly temperature distribution, not being able to meet the regui re ment of batteriy heat dissipation.
What problem does this paper attempt to address?