The torque control of the anterior teeth by using a torque preset arch wire of lingual appliances at the stage of space closure: a 3-dimensional finite element analysis
Jing Li,Dawei Liu,Liang Guo,Qiguo Rong,Yanheng Zhou
DOI: https://doi.org/10.3760/cma.j.issn.1674-5760.2017.04.01
2017-01-01
Abstract:Objective 3D finite element model was used to analyze the influence of the torque preset arch wire on the movement of the anterior teeth.Methods 9°,13°,17°,torque preset arch wire with palatal-only or palatal-buccal combined force loading systems were simulated on the 3D FE model,then the movement tendency of anterior teeth with sliding mechanism was analyzed.Results 1.The 3D finite element model of a torque preset arch wire was established.2.The effects on the movement of the anterior teeth with the increase of torque were as following:With 9° positive torque,the largest movement was in the distal part of lateral incisor,and the distance is 0.194E-3 mm.With 13° positive torque,the largest movement was in the distal part of lateral incisor,and the distance is 0.384E-3 mm.With 17° positive torque,the largest movement was in the distal part of lateral incisor,and the distance is 0.575E-3 mm.3.The effects of different torque combining palatal 1.50N force were that:With 9° positive torque,the largest movement was in the mesial part of canine incisal edge,and the distance is 0.501E-3 mm.With 13° positive torque,the largest movement was in the mesial part of canine incisal edge,and the distance is 0.559E-3 mm.With 17° positive torque,the largest movement was in the mesial part of canine incisal edge,and the distance is 0.628E3 mm.4.Theeffects of different torque combining buccal 1.00N force and palatal 0.50N force were that:With 9°positive torque,the largest movement was in the mesial part of canine cusp,and the distance is 0.340E-3 mm With 13° positive torque,the largest movement was in mesial part of canine cusp,and the distance is 0.499E-3 mm.With 17° positive torque,the largest movement was located in mesial part of canine cusp,and the distance is 0.689E-3 mm.Conclusions The effects on the torque of the anterior teeth by using different torque preset arch wires was different.In order to achieve good torque control,the torque preset arch wire should be used in the stage of space closure by sliding mechanics in lingual appliances.When using the combined forces from palatal and buccal direction,9°-13° positive torque should be used for gaining good incisors torque control.