Effects Of Polytropic Exponent On Data Processing Methods Used In Constant Volume Discharge

yang,lihong,liu,chengliang,zha,xuanfang
DOI: https://doi.org/10.3901/CJME.2008.01.053
IF: 2.964
2008-01-01
Chinese Journal of Mechanical Engineering
Abstract:In order to obtain the accurate sonic conductance of solenoid valves, the polytropic exponent is used in the data processing of the discharge method for measuring the flow rate characteristics of pneumatic components. Three data processing principles are first introduced, and then the discharge pressure data obtained from the measured solenoid valve are processed to obtain the sonic conductance with three methods: the partial polytropic exponent method, the complete polytropic exponent method and the adiabatic method. By comparison of the obtained results it indicates that the complete polytropic exponent method is the most accurate. However, the partial polytropic exponent method is of a high applicable value, because it is easy and simple to measure and the obtained results are relatively accurate.