Advanced treatment of Penicillin wastewater by Fenton oxidation
ZHANG Shichao,YAO Hong,WANG Yukai,Ma Youqian,Tian Sheng,YU Xiaohua
DOI: https://doi.org/10.3969/j.issn.1673-0291.2013.03.009
2013-01-01
Abstract:Fenton oxidation is studied as an advanced treatment process of pharmaceutical wastewater, the effect of pH value, the ratio of H2O2/Fe2+, the concentration of H2O2 and the reaction time on COD removal rate, as well as the relationship among the above factors were investigated by using single factor text. The results of the test show that when the pH value was 3, e ratio of H2O2/Fe2+ was 1:1, the concentration of H2O2 was 300 mg/L and the reaction time was 60 mins, the removal rate of COD reached 59%. And then, based on the single factor test, the regression model related to the removal efficiency of COD, pH value, the ratio of H2O2/Fe2+ and the concentration of H2O2 was obtained by using Design Expert. The regression model would be a fairly reliable forecast for COD removal rate. And, it could be found that the influencing degree of different factors on oxidation performance of Fenton reagent was in the descending order of the concentration of H2O2, the ratio of H2O2/Fe2+, pH value. The optimized parameters were obtained as follows. COD removal rate was 57.415 5%, when pH was 2.98, ratio of H2O2/Fe2+ was 0.76:1, the concentration of H2O2 was 295.10 mg/L.