Smoke Temperature Near the Tunnel Ceiling and above the Fire Source at Different Longitudinal Ventilation Velocities

PENG Wei,HUO Ran,HU Long-hua,ZHONG Wei,YANG Rui-xin
DOI: https://doi.org/10.3969/j.issn.0253-2778.2006.10.008
2006-01-01
Abstract:A series of full scale tests were conducted in two road tunnels.The smoke temperatures near the tunnel ceiling and above the fire source,with different longitudinal ventilation velocities and different typical fire sizes,were measured,presented,and compared with theoretical calculation results.Results suggest that the measured smoke temperature shows good agreement with the calculation results,and is very low when the longitudinal ventilation velocity is fairly large.The cable line-type heat detector can not activate under this condition.Additional fire detection systems based on other fire properties were proposed for use.
What problem does this paper attempt to address?