Abstract:Gas chromatographic methods were studied for the determination of N2O in accelerated aging proppelant with electron capture detector(ECD)and thermal conductivity detector(TCD).The measurement ranges of GC-ECD and GC-TCD,and the influence of different stationary phases and different chromatographic conditions were investigated.The contents of N2O in accelerated aging propellants of different batches were determined by GC-TCD with column of GDX-104 stationary phase.The results demonstrated that the retention time of N2O was 1.6 min,the contents of N2O in accelerated aging propellants of 4 different batches were 376.8,264.7,1036,and 1812 μL/L,respectively,and the RSDs were 4.11%,2.64%,3.87%,and 0.78%,respectively.