Abstract:Purpose:To explore the value of 64-slice spiral CT in detecting thrombosis in the left atrial appendage among the patients with atrial fibrillation.Methods:We evaluated 28 subjects with atrial fibrillation.Each patient received 64-slice spiral CT scan and a transesophageal echocardiography(TEE)within three days.The results of the 64-slice spiral CT were compared with esophageal echocardiography as the gold standard.Results:Among the results of 64-slice spiral CT,33cases accorded with TEE in 37 subjects,diagnose accordance rate was 89.2%.64-slice spiral CT had a sensitivity of 75%,a specificity of 93.1%,a positive predictive value of 75%,and a negative predictive value of 93.1%,when compared with transesophageal echocardiography as the gold standard.The effect of 64-slice spiral CT showed good agreement with TEE(Kappa 0.681).Conclusions:64-slice spiral CT is an accurate method for thrombus detection in the LAA of patients with atrial fibrillation,it may become a screening method for diagnose thrombus in the LAA,it will do great importance to guide therapy,furthermore,it can show the anatomy of the pulmonary veins and left atrial at the same time.