Abstract:Objective To compare the patency of grafted vessels after off-pump coronary artery bypass grafting (OPCABG) and conventional on-pump coronary artery bypass grafting (CCABG). Methods The graft blood flow in 105 patients who received CCABG and 140 patients who underwent OPCABG were determined by transit-time flow meter (TTFM), the mean flow (Qm) and pulsatility index (PI) were recorded. Results No significant difference was found in the general data, and number and type of the grafted vessels between the two groups. The results of TTFM of the internal mammary artery in the OPCABG group [n=101, Qm=(37.2±26.6) ml/min, and PI=3.3±1.3] were similar to those in the CCABG group [n=75, Qm=(39.5±21.8) ml/min, and PI=3.3±1.2; t=-0.612 and 0.000, P>0.05]. Also, no significant difference was detected in the results of TTFM of the great saphenous vein (GSV) between the two groups [OPCABG group: n=335, Qm=(36.8±27.4) ml/min, and PI=3.1±1.5; CCABG group: n=281, Qm=(40.9±26.4) ml/min, and PI=2.9±1.3; t=-1.881 and 1.751, P>0.05]. Moreover, the Qm and PI of the grafted anterior descending, circumflex, and right coronary arteries were similar between the two groups.Conclusions No significant difference exists in the graft blood flow between OPCABG and CCABG groups.