Sensitive determination of nitric oxide in some rat tissues using polymer monolith microextraction coupled to high-performance liquid chromatography with fluorescence detection

Ke-Jing Huang,Min Zhang,Wan-Zhen Xie,Hua-Shan Zhang,Yu-Qi Feng,Hong Wang
DOI: https://doi.org/10.1007/s00216-007-1283-2
2007-01-01
Analytical and Bioanalytical Chemistry
Abstract:A simple, sensitive, selective, and low-cost method is proposed for rapidly determining nitric oxide (NO) in some rat tissues. Polymer monolith microextraction (PMME) using a poly(methacrylic acid–ethylene glycol dimethacrylate) (MAA-EGDMA) monolithic column was combined with derivatization of NO using 1,3,5,7-tetramethyl-8-(3′,4′-diaminophenyl)-difluoroboradiaza- s -indacene (TMDABODIPY), and this was used to analyze the derivatives of NO by high-performance liquid chromatography (HPLC) with fluorescence detection at λ ex / λ em = 498/507 nm. The baseline separation of TMDABODIPY and its NO derivative is performed under simple conditions in which a C 18 column is used and eluted with 50 mmol L −1 ethanolamine and methanol. The conditions for the extraction of NO derivatives were optimized. The limit of detection of NO was 2 × 10 −12 mol L −1 (S/N = 3). The linearity range of the method was 9 × 10 −11 −4.5 × 10 −8 mol L −1 . The interday and intraday relative standard deviations were less than 5%. The proposed method was successfully applied to the determination of NO levels in some rat tissue samples including heart, kidney, and liver with recoveries varying from 87.1 to 95.2%.
What problem does this paper attempt to address?