Test and analysis for conductance of aerospace condenser

Zhang Zhan,Sun Xihui,Huang Zhencheng,Weng Zhili,Chen Yue,Tong Guinian,He Zhenhui,Li Tingxun
DOI: https://doi.org/10.3969/j.issn.1673-1379.2008.04.010
2008-01-01
Abstract:Two phase active thermal control system is one of the main trends for aerospace thermal system in the future. In an active thermal control system, condenser as heat sink is very crucial to electric equipments. In this paper, heat conductance of the tube-plate condenser used in CO2 Mechanically Pumped Two Phase Thermal Control System is studied to evaluate the condenser performance and the test saturated temperatures were found to be 15℃ and -20℃. Compared with the condenser conductance before thermal cycling (-130~20℃), it remained almost unchanged after thermal cycling, which means that the glue used to adhere tubes and condenser plates could stand the extreme thermal temperature without affecting the conductive characteristics.
What problem does this paper attempt to address?