Analysis on progressive collapse resistance of typical high-rise RC frame-shear wall structures

Ren Peiqi,Li Yi,Lu Xinzheng,Ye Lieping
DOI: https://doi.org/10.19701/j.jzjg.2013.23.011
2013-01-01
Abstract:In order to investigate the progressive collapse resistance of high-rise reinforced concrete frame-shear wall structures designed according to Code for design of concrete structures(GB 50010—2010),two 15-storey RC frame-shear wall building models with different typical structural layouts were analyzed.Linear static alternative load path method was applied for the progressive collapse prevention design of a building and the reliability and economical efficiency of this method to be used for the collapse prevention design for high-rise RC frame-shear wall structures were verified.The results show that significant differences exist in the progressive collapse resistance of high-rise RC frame-wall structures.When parts of the shear-walls are destroyed,if the shear-walls are connected to each other,then the residual structures will have good ability to redistribute the internal forces to resist progressive collapse.Progressive collapse resistance of the frame part depends on the redundancy of the structural design.If the design is conservative,then the frame has good performance in progressive collapse prevention.However,if the design follows the minimum requirement of Chinese design specification,the frame cannot efficiently resist progressive collapse and needs additional progressive collapse prevention design.The linear static alternative load path method proposed by Tsinghua University has enough safety and a certain economy to be used in the progressive collapse prevention design of structures.
What problem does this paper attempt to address?