Evaluation of digital mammography in the diagnosis of nonpalpable breast cancer

LIU Xiao-jie,ZOU Li-qiu,ZHAO Yan,CHEN Sheng-zhong,WU Xin-bing
DOI: https://doi.org/10.3969/j.issn.1009-3257.2007.05.006
2007-01-01
Abstract:Objective To evaluate the full-field digital mammography in the diagnosis of nonpalpable breast cancer. Methods 43 cases of nonpalpable tumor on digital mammogram were found in physical examination, All were verified by pathological examination.Routine positions of Full-field digital mammography were used in all patients including the craniocaudal projection(CC) and the mediolateral oblique projection(MLO), spot compression and magnification was performed when it was necessary. X-ray guided wire localization was conducted before operation. Results Microcalcifications were found on digital mammogram in 18 cases,3of these was disease before cancer,5 were ductal carcinoma in situ,10 were infiltrating ductal carcinoma; Micronodule or local hyperdensity on mammogram with calcification was found in 9 cases,1 was disease before cancer and 5 were lobubar carcinoma in situ ,3 were DCIS;Of 7 cases with asymmetrical increase of local density on mammogram,2 was lobubar carcinoma in situ, 5 were infiltrating ductal carcinoma; Multilobular small nodes was found in 6 cases,2 was DCIS,4 were infiltrating ductal carcinoma; Architectural distortion was found in 3 case,pathological examination were infiltrating ductal carcinoma. Conclusion It is high sensitivity of full-field digital mammography in diagnosing nonpalpable breast cancer,improving life quality and subsistence rate,decreasing mortality rate and performing partial breast operation.
What problem does this paper attempt to address?