Determination of Fentanyl in Human Plasma by HPLC-MS-MS and Study on Its Bioequivalence

TIAN Ying-ying,WANG Yi-cheng,WU Hui-bin,DENG Xiao-lan,TAN Zhi-rong,ZHOU Hong-hao,OUYANG Dong-sheng
2012-01-01
Abstract:AIM: To establish an HPLC-MS/MS assay to determine fentanyl in human plasma.METHODS: D-fentanyl was used as an interal standard.Human plasma samples were extracted by n-hexane.The separation was carried out on an Thermo Hypurity C18(150 mm×2.1 mm,5 μm) column at 40 ℃.The mobile phase consisted of methanol-0.1% formic acid(85∶15,V/V) at a flow rate of 0.3 mL/min.Electrospray ionization(ESI) source was applied and operated in the positive ion mode.Quantitaion was performed using multiple reaction monitoring(MRM) of the m/z 337.1→188.1 for fentanyl,and m/z 341.9→187.9 for D-fentanyl.RESULTS:The liner calibration curves were obtained in the range of 19.53-5000 pg/mL for fentanyl.The lower limit of quantification was 19.53 pg/mL.The relative standard deviation of the intra-assay and inter-assay precision of variation was less than 5.16%.The extraction recovery for fentanyl was above 90%.To study the pharmacokinetics of two transdermal patches of fentanyl,preparations were given to 24 healthy volunteers,and the relative bioavailability of AUC0-144 was(94.0±19.5)%.CONCLUSION: It is an accurate,sensitive and rapid method that can be applied to determine fentanyl in human plasma.Two preparations of fentanyl are bioequivalent.
What problem does this paper attempt to address?